Videnskablig dokumentation

1.

medRxiv

UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication

Abstract

The potential virucidal effects of UV-C irradiation on SARS-CoV-2 were experimentally evaluated for different illumination doses and virus concentrations (1000, 5, 0.05 MOI). At a virus density comparable to that observed in SARS-CoV-2 infection, an UV-C dose of just 3.7 mJ/cm2 was sufficient to achieve a more than 3-log inactivation without any sign of viral replication. Moreover, a complete inactivation at all viral concentrations was observed with 16.9 mJ/cm2. These results could explain the epidemiological trends of COVID-19 and are important for the development of novel sterilizing methods to contain SARS-CoV-2 infection.

Introduction

The COVID-19 pandemic caused by SARS-CoV-2 virus1 has had an enormous, as yet barely understood, impact on health and economic outlook at the global level2. The identification of effective microbicide approaches is of paramount importance in order to limit further viral spread, as the virus can be transmitted via aerosol3,4 and can survive for hours outside the body57. Non-contact disinfection technologies are highly desirable, and UV radiation, in particular UV-C (200 – 280 nm) has been suggested to be able to inactivate different viruses, including SARS-CoV812. The interaction of UV-C radiations with viruses has been extensively studied1315, and direct absorption of the UV-C photon by the nucleic acid basis and/or capsid proteins leading to the generation of photoproducts that inactivate the virus was suggested to be one of the main UV-C-associated virucidal mechanisms16,17. Some models have been proposed to correlate the nucleic acid structure with the required dose to inactivate the virus, but a reliable model is still unavailable18. This is also due to the fact that UV-C measurements were conducted using different viruses and diverse experimental conditions1922. This led to an extremely wide range of values for the same virus and, e.g., in the case of SARS-CoV-1 values reported in the literature range from a few mJ/cm2 to hundreds mJ/cm219,22,23. Likewise, recent papers reported values for UVC inactivation ranging from 3 to 1000 mJ/cm2 24–27. A better understanding of the effects of UV-C on SARS-CoV-2, which take into account all the key factors involved in the experimental setting (including culture medium, SARS-CoV-2 concentration, UV-C irradiance, time of exposure, and UV-C absorbance) will allow to replicate the results in other laboratory with different devices. Moreover, as recent evidences suggest that UV light from sunlight are efficient in inactivating the virus28, these measurements will be relevant for the setting up of further experiment considering the role of UV-A and UV-B on SARS-CoV-2 replication.

Results and discussion

Herein, we report the effect of monochromatic UV-C (254 nm) on SARS-CoV-2, showing that virus inactivation can be easily achieved. Experiments were conducted using a custom-designed low-pressure mercury lamp system, which has been spectral-calibrated providing an average intensity of 1.082 mW/cm2 over the illumination area (see the details reported in the Method section). Three different illumination exposure times, corresponding to 3.7, 16.9 and 84.4 mJ/cm2, were administered to SARS-CoV-2 either at a multiplicity of infection (MOI) of 0.05, 5, 1000. The first concentration is equivalent to the low-level contamination observed in closed environments (e.g. hospital rooms), the second one corresponds to the average concentration found in the sputum of COVID-19 infected patients, and the third one is a very large concentration, corresponding to that observed in terminally diseased COVID-19 patients29. After UV-C exposure, viral replication was assessed by culture-polymerase chain reaction (C-RT-PCR) targeting two regions (N1 and N2) of the SARS-CoV-2 nucleocapsid gene, as well as by analyzing SARS-CoV-S2-induced cytopathic effect. Analyses were performed in the culture supernatant of infected cells at three different time points (24, 48 and 72 hours for SARS-CoV-2 at MOI 1000 and 5; 24, 48 hours and 6 days for SARS-CoV-at MOI 0.05), as well as on cell lysates at the end of cellular culture (72 hours: MOI 1000 and 5; 6 days: MOI 0.05). This approach allows to follow the kinetic of viral growth and to verify whether the used dose is sufficient to completely inactivate the virus over time. This is useful from a practical point of view, when UV-C devices are used to disinfect surfaces and the environment.

The effect of the UV-C exposure on SARS-CoV-2 replication was extremely evident and independent from the MOI employed; dose-response and time-dependent curves were observed. Figure 12 and 3 report for different MOI the number of SARS-CoV-2 copies for the three concentrations as a function of the UV-C dose and time, quantified on a standard curve from a plasmid control. The corresponding normalised curves of the virus copies are reported in the same figures.

Figure 1.

Figure 1.Viral replication of UV8irradiated SARS8CoV82 (0.05 MOI) virus in in vitro VeroE6 cells.

Vero E6 cells were infected with UV-C irradiated SARS-CoV-2 virus at a MOI of 0.05. Culture supernatants were harvested at the indicated times (24, 48 hours and 6 days) and virus titers were measured (Panel A, B) by absolute copy number quantification (Real-Time PCR). Viral replication was assessed even on cell lysate harvested at the end of cell cultures (6 days) (Panel C). All cell culture conditions were seeded in duplicate. Panel D reports the plots of the measured virus copies normalized at the untreated sample in the different conditions. For descriptive purposes, mean values and whiskers representing the observed half-ranges are shown.

Figure 2.

Figure 2.Viral replication of UV8irradiated SARS8CoV82 (5 MOI) virus in in vitro VeroE6 cells.

Vero E6 cells were infected with UV-C irradiated SARS-CoV-2 virus at a MOI of 5. Culture supernatants were harvested at the indicated times (24, 48 and 72 hours) and virus titers were measured by absolute copy number quantification (Real-Time PCR, A and B). Viral replication was assessed even on cell lysate harvested at the end of cell cultures (72 hours) (C). All cell culture conditions were seeded in duplicate. Panel D reports the plots of the measured virus copies normalized at the untreated sample in the different conditions. For descriptive purposes, mean values and whiskers representing the observed half-ranges are shown.

Figure 3.

Figure 3.Analyses of virus induced cytopathic effect.

(A) No cytopathic effect was observed in uninfected cultured VeroE6 monolayers maintained in 50mJ/cm2 UV-treated complete medium for 72 hours. (B) In vitro infection of SARS-CoV-2 (5 MOI) UV-C untreated VeroE6 cells resulted in an evident cytopathic effect. (C) SARS-CoV-2 irradiation with 3.7 mJ/cm2 UV-C rescued the cytopathic effect induced by UV-C untreated virus.

Viral replication was not observed at the lowest viral concentration (0.05 MOI) in either untreated or in UV-C-irradiated samples in the initial 48 hours (Figure 1). However, 6 days after infection, viral replication was distinctly evident in the UV-C unexposed condition, but was completely absent following UV-C irradiation even at 3.7 mJ/cm2 both in cell culture supernatants (Figure1, panel A and B) and in cell lysate (Figure 1, panel C). A two-way ANOVA analysing the effect of UV-C dose and time of incubation failed to identify a significant effect of the UV exposure on viral replication. This is due to the fact that at very low MOI relevant increases in N1 and N2 copy numbers were detectable only in a single condition -at six days in the absence of UV-C exposure-thus hampering the statistical power of the analysis.

At the intermediate viral concentration (5 MOI), a significant reduction of copy number starting from the 3.7 mJ/cm2 dose with a decrease of a factor of 2000 (> 3-log decrease) after 24 hours was observed (Figure 2, panel D). A two-way ANOVA confirmed that this UV-C dose significantly dampened viral replication (p=0.000796, and P=0.000713 for N1 and N2 copies respectively). Even more important, the copy number did not increase over time, suggesting an effective inactivation of the virus, which was further confirmed by cytopathic effect assessment (Figure 3, panel A, B and C).

Using a high viral input (MOI=1000), the two-way ANOVA confirmed that all the tree UV doses analysed resulted in a significant suppression of viral replication for both N1 (3.7 mJ/cm2: p= 0.008455; 16.9 mJ/cm2: p=0.004216; and 84.4 mJ/cm2: p=0.000202) and N2 copies (3.7 mJ/cm2: p= 6.43E-05; 16.9 mJ/cm2: p=1.68E-05; and 84.4 mJ/cm2: p=1.68E-05)(Figure 4). Notably, a different course of infection was observed, in which the inhibitory effect was not accompanied by viral suppression for the UV-C dose of 3.7 mJ/cm2 (Figure 4, panel A, B and D). Indeed, a relevant reduction in N1 e N2 copy numbers was observed in a UV-C dose-dependent manner as early as 24 hours (by a factor of 103 at 3.7 mJ/cm2 and 104 at 16.9 mJ/cm2Figure 4, panel A, B and D), but longer culture times resulted in an increase in N1 and N2 copy numbers for the UV-C dose of 3.7 mJ/cm2. This indicates that the residual viral input left by the 3.7 mJ/cm2 was able to replicate and suffucient to generate an effective infection. This is not the case in cultures exposed to higher UV-C doses, as no replication could be detected in these conditions. All the results were further confirmed by 2-ANOVA statistical analyses performed on viral replication at intracellular level (3.7 mJ/cm2 vs. Untreated: N1, p=0.008455; N2: p=6.43E-05; 16.9 mJ/cm2 vs. Untreated: N1, p=0.004216; N2: p=1.68E-05; 84.4 mJ/cm2 vs. Untreated: N1, p=0.004216; N2: p=1.68E-05) (Figure 1, panel C; Figure 2, panel C; Figure 4, panel C).

Figure 4.

Figure 4.Viral replication of UV8irradiated SARS8CoV82 (1000 MOI) virus in in vitro VeroE6 cells.

Vero E6 cells were infected with UV-C irradiated SARS-CoV-2 virus at a MOI of 1000. Culturesupernatants were harvested at the indicated times (24, 48 and 72 hours) and virus titers were measured (Panel A, B) by absolute copy number quantification (Real-Time PCR). Viral replication was assessed even on cell lysate harvested at the end of cell cultures (72 hours) (Panel C). All cell culture conditions were seeded in duplicate. Panel D reports the plots of the measured virus copies normalized at the untreated sample in the different conditions. For descriptive purposes, mean values and whiskers representing the observed half-ranges are shown.

We compared our results with data available in the literature and observed that our inactivating dose is much smaller than that reported in Heilingloh et al.26 (1000 mJ/cm2 for the complete inactivation). This discrepancy is likely to be the consequence of the UV-C absorption by the medium used in Heilingloh et al, which has a 4-fold higher thickness compared to the one used in our experiments. This possibility is supported by the observation that 200 mJ/cm2 of UV-A, which is not absorbed by the medium, was sufficient to reduce viral replication of 1-log. As UV-A light is significantly less efficient (order of magnitudes) than UV-C, the reported UV-C inactivating dose (100mJ/cm2) seems to be questionable. Two other papers measured the effect of UV-C light on SARS-CoV-2. In Ruetalo et al.25, the illumination of 254 nm light was employed on a dried sample of SARS-CoV-2. Complete inactivation was obtained with 20 mJ/cm2, a value greater than ours, but in the same range. It has to be underlined that in the dried film a shielding effect by the organic component present in the liquid can occur, reducing the efficiency of the UV-C light. This was shown by Ratnesar-Shumate et al.28, who demonstrated that the dose required to obtain a similar degree of viral inactivation was twice in dried samples from gMEM compared to the ones resuspended in simulated saliva. Notably, the two mediums differ for their composition, mainly in terms of protein and solid percentage, with higher values for the gMEM.

Inagaki et al. used a 285 nm UV LED and showed that a dose of about 38 mJ/cm2 was sufficient to completely inactivate SARS-CoV-2. This dose is greater compared to the one we established; this discrepancy can be explained by the observation that the 285 nm is less efficient than the 254 nm wavelength24. Finally, in an elegant study Storm et al.27 compared the virucidal effect of UV-C in wet and dry systems. Results were based on the use of a very small volume of viral stock in DMEM (5 μl) and showed that a dose of 3.4 mJ/cm2 inactivated wet samples, whereas a dose that twice as high was needed in dried samples. These results are comparable to the ones herein, and the shielding effect in dried samples is almost evident. Such comparisons show how the experimental conditions adopted significantly impact on the definition of the dose of UV-C resulting in virus inactivation. It is therefore crucial to accurately describe all the details of the experiments to perform a reliable comparison.

In conclusion, we report the results of a highly controlled experimental model that allowed us to identify the UV-C radiation dose sufficient to inactivate SARS-CoV-2. The response depends on both the UV-C dose and the virus concentration. Indeed, for virus concentrations typical of low-level contaminated closed environment and sputum of COVID-19 infected patients, a very small dose of less than 4 mJ/cm2 was enough to achieve full inactivation of the virus. Even at the highest viral input concentration (1000 MOI), viral replication was totally inactivated with a dose >16.9 mJ/cm2. These results show how the SARS-CoV-2 is extremely sensitive to UV-C light and they are important to allow the proper design and development of efficient UV based disinfection methods to contain SARS-CoV-2 infection.

Methods

In vitro SARS8CoV82 infection assay

3 × 105 VeroE6 cells were cultured in DMEM (ECB7501L, Euroclone, Milan, Italy) with 2 % FBS medium, with 100 U/ml penicillin and 100 μg/ml streptomycin, in a 24-well plate one day before viral infection assay. SARS-CoV-2 (Virus Human 2019-nCoV strain 2019-nCoV/Italy-INMI1, Rome, Italy) at a multiplicity of infection (MOI) of 1000, 5 and 0.05 were treated with different doses of UV-C radiation (see the dedicated section) before inoculum into VeroE6 cells. UV-C-untreated virus served as positive controls. Cell cultures were incubated with the virus inoculum in duplicate for three hours at 37°C and 5% CO2. Then, cells were rinsed three times with warm PBS, replenished with the appropriate growth medium and observed daily for cytopathic effect. Viral replication in culture supernatants was assessed by an Integrated Culture-polymerase chain reaction (C-RT-PCR) method30 at 24, 48, and 72 hours post-infection (hpi) while infected cells were harvested for RNA collection at 72 hpi. Cell cultures from SARS-CoV-2 at 0.05 MOI were harvested 6 days post infection. RNA was extracted from VeroE6 cell culture supernatant and cell lysate by the Maxwell® RSC Instrument with Maxwell® RSC Viral Total Nucleic Acid Purification Kit (Promega, Fitchburg, WI, USA), quantified by the Nanodrop 2000 Instrument (Thermo Scientific) and purified from genomic DNA with RNase-free DNase (RQ1 DNase; Promega). One microgram of RNA was reverse transcribed into first-strand cDNA in a 20-μl final volume as previously described31,32.

Real-time PCR was performed on a CFX96 (Bio-Rad, CA, USA) using the 2019-nCoV CDC qPCR Probe Assay emergency kit (IDT, Iowa, USA), which targets two regions (N1 and N2) of the nucleocapsid gene of SARS-CoV-2. Reactions were performed according to the following thermal profile: initial denaturation (95°C, 10 min) followed by 45 cycles of 15 s at 95°C (denaturation) and 1 min at 60°C (annealing-extension). Viral copy quantification was assessed by creating a standard curve from the quantified 2019-nCoV_N positive Plasmid Control (IDT, Iowa, USA).

UV illumination test

The illumination of the virus solution was conducted using a low-pressure mercury lamp mounted in a custom designed holder, which consist in a box with a circular aperture 50 mm in diameter placed at approximately 220 mm from the source. The aperture works as a spatial filter to make the illumination of the area behind more uniform. A mechanical shutter is also present to start the illumination process. The plate is placed 30 mm below the circular aperture and a single dwell (34.7 mm in diameter), centered in respect to the 50 mm aperture, has been irradiated from the top. The dwell was filled with 0.976 ml of the virus suspended in Dulbecco’s Modified Eagle’s Medium (DMEM) in order to have a 1 mm thick liquid layer. After the irradiation, the sample was treated as described in the previous section.

The intensity of the lamp and its spectral properties have been measured using an Ocean Optics HR2000+ spectrometer (Ocean Optics Inc., Dunedin, USA). The HR2000+ spectrometer was calibrated against a reference deuterium–halogen source (Ocean Optics Inc. Winter Park, Winter Park, Florida) and in compliance with National Institute of Standards and Technology (NIST) practices recommended in NIST Handbook 150-2E, Technical guide for Optical Radiation Measurements. The last calibration was performed in March 2019. The detector of our spectrometer is a high-sensitivity 2048-element Charge-Coupled Device (CCD) array from Sony. The spectral range is 200–1100 nm with a 25 μm wide entrance slit and an optical resolution of 1.4 nm (FWHM). The cosine-corrected irradiance probe, model CC-3-UV-T, is attached to the tip of a 1 m long optical fibre and couples to the spectrometer. The intensity of the lamp has been measured by positioning the spectrometer in five positions: in the center and at the ends of a 20 mm cross arm after a warming up time of 30 s. The spectra in the five positions are reported in Figure 5 (Panel A) together with a scheme of the dwell and illuminated area.

Figure 5.

Figure 5.

Mercury lamp spectrum measured in the five positions (Panel A). Inset: scheme of the illuminated dwell and the measuring position. UVXvis transmission spectrum of the Dulbecco’s Modified Eagle’s Medium (DMEM) in a 1 mm quartz cuvette (Panel B).

As expected, the emission is dominated by the UV-C line (Figure 5, Panel A) and its intensity was uniform in the area with an average value of 1.082 mW/cm2. The stability of the lamp was evaluated in +/-11E-3 mW/cm2 during a 130 s measurement. According to this value, three exposure times were set: 5, 23 and 114 s (with an accuracy of 0.2s), which correspond to following doses: 5.4, 25.0, 123.4 mJ/cm2. This is the nominal UV doses provided to the dwell, but we were interested in the effective doses (De) reaching the virus. It was necessary to calculate the effective irradiance (Ie). This step was performed considering both the reflection losses at the air/water interface (Rw) and the Transmittance (Ts) of the DMEM solution at 254 nm (from the spectrum in figure 5, Panel B, considering the cuvette losses, Ts = 0 .70). It is important to notice that the spectrum was measured in a quartz cuvette (1 mm thick) by means of a Jasco V770 spectrophotometer and this thickness was the same of the solution in the dwell during the UV irradiation step.

The reflection loss was computed as follow:Embedded ImageWhere nw = 1.375 is the refractive index of water at 254 nm. Then, Ie was calculated:Embedded ImageThe final transmission of the DMEM solution was equal to 0.68 and the corresponding effective doses were derived simply multiplying Ie by the exposure time.

According to this value, the effective doses provided to the viruses were: 3.7±0.15, 16.9±0.2 and 84.4±0.9 mJ/cm2. We have to notice that we are neglecting here the absorption of the virus at this wavelength and the possible scattering. Such approximations are valid considering the relative low concentration of the virus and small thickness of the layer (the solution appeared fully transparent).

Statistical analyses

To assess the effect of the different UV-C doses on N1 and N2 copy numbers, two-way ANOVAs were performed. For the analysis of intracellular N1 and N2 doses in the supernatant, UV-C dose and MOI represented the dependent variables, while for the analysis of N1 and N2 in the supernatant, different analyses were performed for individual MOI, using UV-C dose and time as dependent variables.

Author Contribution

P.G., L.L. E.R. and A.Z. designed and produced the illumination system; A.C., C.C. and M.L. performed the lamp calibration; A.B. performed the lamp setup and lamp dosimetry, wrote the main manuscript; M.B. performed biological experiments, analyzed the data, wrote the main manuscript; C.F., I.S. designed and performed some biological tests; E.T, A.A. performed the statistical analysis; D.T. discussed the results; G.P. and M.C. supervised the study and review the manuscript.

Acknowledgements

This research was partially supported by a grant from Falk Renewables and it has been carried out in the context of the activities promoted by the Italian Government and in particular, by the Ministries of Health and of University and Research, against the COVID-19 pandemic. Authors are grateful to INAF’s President, Prof. N. D’Amico, for the support and for a critical reading of the manuscript.


2.

LINK til: ScienceDirect https://www.sciencedirect.com/science/article/pii/S0196655320307562
Eller læs mere herunder.

Susceptibility of SARS-CoV-2 to UV irradiation

Author links open overlay panelChristiane SilkeHeilinglohPhD1Ulrich WilhelmAufderhorst12LeonieSchipperBSc1UlfDittmerPhD24OliverWitzkeMD1DongliangYang34XinZheng34KathrinSutter24MirkoTrillingPhD24MiraAltMSc1EikeSteinmann5#AdalbertKrawczykPhD124#1Department of Infectious Diseases, West German Centre of Infectious Diseases, Universitätsmedizin Essen, University Duisburg-Essen, Germany2Institute for Virology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany3Hust Huazhong University of Science & Technology, Wuhan Union Hospital, Department of Infectious Diseases, Wuhan, China4Wuhan-Essen Joint International Laboratory of Infection and Immunity, Essen, Germany5Department of Molecular and Medical Virology, Faculty of Medicine, Ruhr University Bochum, Bochum, Germany

Highlights

SARS-CoV-2 is highly susceptible to irradiation with ultraviolet light.•

High viral loads of 5 * 106 TCID50/ml SARS-CoV-2 can be inactivated in 9 minutes by UVC irradiation.•

UVC irradiation represents a suitable disinfection method for SARS-CoV-2.

Abstract

The coronavirus SARS-CoV-2 pandemic became a global health burden. We determined the susceptibility of SARS-CoV-2 to irradiation with ultraviolet light. The virus was highly susceptible to ultraviolet light. A viral stock with a high infectious titer of 5 × 106 TCID50/mL was completely inactivated by UVC irradiation after nine minutes of exposure. The UVC dose required for complete inactivation was 1,048 mJ/cm2. UVA exposure demonstrated only a weak effect on virus inactivation over 15 minutes. Hence, inactivation of SARS-CoV-2 by UVC irradiation constitutes a reliable method for disinfection purposes in health care facilities and for preparing SARS-CoV-2 material for research purpose.

Background

In December 2019, a novel coronavirus causing severe acute respiratory disease (SARS-CoV-2) was newly identified in the Hubei province, PR China, before becoming a global pandemic and causing tremendous health and socio-economic burdens.1 At the time of writing, more than 14.9 million cases and >618,000 deaths were reported worldwide (2020.07.23). The actual number of people infected with SARS-CoV-2 is most likely to be much higher since numerous infections, especially in younger people, are asymptomatic and frequently not captured by routine diagnostic methods.2 The symptoms of COVID-19 range from mild respiratory illness accompanied by cough, fever, myalgia, and fatigue, to severe, life-threatening pneumonia, and acute respiratory distress syndrome.3 Clearly, the prevention of the transmission of respiratory infections especially within hospitals or other institutions is of central importance. The disinfection of objects using UV-irradiation is an environmentally friendly method of killing bacteria, fungi and viruses without the use of harmful chemicals or heat. Consequently, UV light disinfection is becoming increasingly applied in healthcare facilities for disinfecting healthcare equipment, surfaces, and operating rooms.4 However, the efficacy of UV irradiation on the inactivation of SARS-CoV-2 in fluids has not been described thus far. In the present study, we investigated the susceptibility of high titer viral stocks of SARS-CoV-2 to combined or separate UVA and/or UVC irradiation.

Material and Methods

Isolation of SARS-CoV-2 from a nasopharyngeal swab

A clinical isolate of SARS-CoV-2 was isolated from a nasopharyngeal swab of a patient suffering from COVID-19 disease. The patient was hospitalized at the Department of Infectious Diseases of the University Hospital Essen. The swab was taken using a Virocult vial (Sigma, Germany). The Virocult medium was then incubated on Vero E6 cells cultured in DMEM containing 10% (v/v) fetal calf serum and supplemented with Penicillin (100 IU/mL), Streptomycin (100 µg/mL), Ciprofloxacin (10 µg/mL), and Amphotericin B (2.5 µg/mL). After 5 days of incubation, the supernatant was harvested and cell debris was removed by centrifugation. Afterwards, 100 µL of the clear supernatant was used for subsequent infection of a new Vero E6 cell culture flask. After 5 days of incubation, supernatants were found to be positive for SARS-CoV-2 by a conventional qualitative PCR. The virus suspension was harvested and cleared from cellular debris by centrifugation and stored at −80°C. Viral titers were determined by endpoint dilution assay and the 50% tissue culture infective dose (TCID50) was calculated.

Inactivation of SARS-CoV-2 by UV-irradiation

To determine the susceptibility of SARS-CoV-2 to UVA and/or UVC irradiation, a viral stock at a concentration of 5 × 106 TCID50/mL was irradiated with UV light for up to 30 minutes. UV exposure was performed by separate or combined irradiation with UVC (254 nm) and/or UVA (365 nm) of 600 µL virus stock in 24-well plates. The UV light source (UV-4 S/L, order no. 2950440, Herolab, Wiesloch, Germany) was placed at a distance of 3 cm above the bottom of the plate. The emitted light intensity was UVC (254 nm) = 1940 µW/cm2 and UVA (365 nm) = 540 µW/cm2 at a distance of 3 cm, as measured by radiometric analysis. This corresponds to an applied light dose of 1.94 mJ/cm2 per second for UVC and 0.54 mJ/cm2 per second for UVA, while µW = 10−6 J/s. The samples were taken after 0, 3, 6, 9, 12, 15, 18, 21, 24, 27, and 30 minutes of combined UVA and UVC irradiation. Samples irradiated with UVA were taken after 0, 3, 6, 9, 12, 15 minutes, and after UVC-irradiation after 0, 1, 2, 3, 6, 9, and 15 minutes. The TCID50/ml concentration of each sample was determined by endpoint dilution, respectively.

Results

SARS-CoV-2 showed high susceptibility to UV irradiation. Total inactivation of SARS-CoV-2 at a concentration of 5 × 106 TCID50/mL was achieved after 9 minutes of combined UVA and UVC exposure (Fig 1A). As calculated by nonlinear regression, 50% of the virus could be inactivated after 1.4 minutes of UV-treatment (Fig 1B). UVA exposure alone was less effective on virus inactivation. After 9 minutes of irradiation and an emitted dose of 292 mJ/cm2, 1 log reduction of the viral load was observed. In contrast, complete virus inactivation was achieved after a 9 minute exposure to UVC and an emitted UVC dose of 1048 mJ/cm2. These data confirm former findings that UVC is more effective in inactivating viruses, and highlight UVC irradiation as an effective method for the inactivation of SARS-CoV-2.

Fig 1

Discussion

In the present study, we demonstrated that SARS-CoV-2 could effectively be inactivated by UVC irradiation, even at high viral titers, whereas UVA-irradiation was much less effective. These data are in line with previous reports where other coronaviruses eg, SARS-CoV-1 were shown to be susceptible to UVC irradiation.567 Viral stocks with titers of 1 × 106 TCID50/mL of SARS-CoV-1 could be almost completely inactivated after 6 minutes of UVC-irradiation, corresponding to a UVC dose of 1446 mJ/cm2.5 In our study, the emitted dose required for a complete inactivation of SARS-CoV-2 was 1048 mJ/cm2 after 9 minutes of exposure. A similar dose of 1 J/cm2 was also required to inactivate a viral load of 1 * 106 TCID50 H1N1 influenza virus.7 UV light disinfection is chemical free and thus a suitable method for applying in healthcare facilities to disinfect healthcare equipment.4 Most recently, a protocol for the disinfection of personal protective equipment including filtering face pieces from health care workers described the potential use of ultraviolet light to inactivate SARS-CoV-2.6 Taken together, we demonstrated that UV irradiation is a highly effective method to inactivate the new corona virus SARS-CoV-2, even at the higher viral load levels that are found in research laboratories eg, in cell-culture supernatants or in diagnostic material taken from the respiratory tract of COVID-19 patients.

Conclusion

We demonstrated that SARS-CoV-2, even at high viral titers, could be inactivated rapidly by UVC irradiation, revealing that this method is reliable not only for disinfection purposes in health care facilities but also for preparing inactivated SARS-CoV-2 material for research.

Acknowledgments

This study was supported by the Stiftung Universitätsmedizin Essen (awarded to K. Sutter, M. Trilling and A. Krawczyk) and the Rudolf Ackermann Foundation (awarded to O. Witzke). The authors thank Delia Cosgrove for the proofreading of the manuscript.

References

1N Zhu, D Zhang, W Wang, et al.A novel coronavirus from patients with pneumonia in China, 2019N Engl J Med, 382 (2020), pp. 727-733CrossRefView Record in ScopusGoogle Scholar2R Li, S Pei, B Chen, et al.Substantial undocumented infection facilitates the rapid dissemination of novel coronavirus (SARS-CoV-2)Science, 368 (2020), pp. 489-493CrossRefView Record in ScopusGoogle Scholar3WJ Guan, ZY Ni, Y Hu, et al.Clinical characteristics of coronavirus disease 2019 in ChinaN Engl J Med, 382 (2020), pp. 1708-1720CrossRefView Record in ScopusGoogle Scholar4B Casini, B Tuvo, ML Cristina, et al.Evaluation of an ultraviolet C (UVC) light-emitting device for disinfection of high touch surfaces in hospital critical areasInt J Environ Res Pub Health, 16 (2019)Google Scholar5ME Darnell, K Subbarao, SM Feinstone, DR TaylorInactivation of the coronavirus that induces severe acute respiratory syndrome, SARS-CoVJ Virol Methods, 121 (2004), pp. 85-91ArticleDownload PDFView Record in ScopusGoogle Scholar6WA Anderson, JGB Derraik, EA Connelly, YC AndersonRapid evidence summary on SARS-CoV-2 survivorship and disinfection, and a reusable PPE protocol using a double-hit processmedRxiv (6 Apr 2020)[Epub ahead of print]. Available at:https://www.medrxiv.org/content/10.1101/2020.04.02.20051409v1, Accessed 25th Aug 2020Google Scholar7DH Brian HeimbuchResearch to mitigate a shortage of respiratory protection devices during public health emergenciesApplied Research Associates (2019)Available at:https://www.ara.com/sites/default/files/ARAReviewN95FFRDecontamination.pdf, Accessed 19th Aug 2020Google Scholar

Conflicts of interest: None to report.

Author Contributions: C.S. Heilingloh, U. Dittmer, O. Witzke: study design, data collection, data interpretation; U.W. Aufderhorst, L. Schipper, M. Alt: experiments, data analysis, data interpretation; D. Yang, X. Zheng, K. Sutter, M. Trilling: data analysis, data interpretation; writing; C.S. Heilingloh, E. Steinmann, A. Krawczyk study design, writing, figure design.#

HOV! Vi henvender os først og fremmest til erhverv. Vi bruger ikke Cookies. Vores websted bruger ikke "cookies". Vi tillader dog brug af cookies i forbindelse med sikkerheden af vores websted. Du kan som bruger vælge at indstille webbrowser til at nægte cookies, det er dog ikke nødvendigt, da vi har en politik til brug af non cookies. Vælge du som virksomhed at handle på vores hjemmeside, gemmes data om dit køb.